SPECIFICATIONS
• N-KNX34. KNX/EIB USB Programming Interface Module.
Power supply: KNX line, 21…30 VDC.
Current consumption (max.): < 5 mA.
USB connection: USB2.0 connector.
• N-KNX18. KNX/EIB Power Supply Module.
Power supply: 230 VAC.
Maximum load: 640 mA.
Output voltage: 24 VDC.
• N-KNX29. KNX/EIB Temperature Sensor Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2mm safety sockets.
Range measurement: 0-40 ºC (approx.).
• N-KNX1. KNX/EIB Heating Actuator Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX31. KNX/EIB Valve Actuator Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
Hydroelectric valve with automatic flow regulation.
• N-KNX30. KNX/EIB Touch Panel Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX25. KNX/EIB Single Line Extending Bus Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
Interconnection with other KNX/EIB systems.
• N-KNX2. KNX/EIB Additional Power Supply Module.
KNX bus voltage: 28 VDC.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX32. KNX/EIB Weather Station Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2mm safety sockets.
Different configurations:
Day/night.
Winter/summer.
This module allows measure:
Outside temperature.
Wind speed.
Solar azimuth.
Level of external brightness.
• N-KNX17. KNX/EIB Movement Sensor Module.
Movement sensor for bus system KNX.
Max. Transmission range frontally 7 m.
Number of channels 1.
• All necessary cables to realize the practical exercises are included.
Cables and Accessories, for normal operation.
AEL-KNX2 | KNX/EIB HEATING CONTROL APPLICATION
The KNX/EIB Heating Control Application, “AEL-KNX2”, has been designed by Edibon to show the users the most important KNX elementsused in the most advanced heating control installations. Temperature control is carried out through temperature sensors and actuators thatenable/disable the boiler with a constant integrated close loop control.
The purpose of the AEL-KNX2 is to give the students a complete practical and theoretical training in the installations and programmingof the most important KNX elements focused in heating control systems, characteristic of sensors, actuators, study of energy consumptionwith these heating control systems, etc.
To take a maximum experience with the KNX/EIB Heating Control Application is very recommendable to acquire the rest of the KNX offeredby Edibon: AEL-KNX1, AEL-KNX3, AEL-KNX4 and AEL-KNX5. The combination of all these applications allows the student to design acomplete intelligent bus system implemented by a KNX System.
In addition, this application requires the ETS latest generation KNX software to program different scenes, import of KNX projects, settingof sensors and actuators, etc.