SPECIFICATIONS
• N-KNX34. KNX/EIB USB Programming Interface Module.
Power supply: KNX line, 21…30 VDC.
Current consumption (max.): < 5 mA.
USB connection: USB2.0 connector.
• N-KNX18. KNX/EIB Power Supply Module.
Power supply: 230 VAC.
Maximum load: 640 mA.
Output voltage: 24 VDC.
• N-KNX5. KNX/EIB Binary Output Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX4. KNX/EIB Binary Input Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX17. KNX/EIB Movement Sensor Module.
Movement sensor for bus system KNX.
Max. Transmission range frontally 7 m.
Number of channels 1.
• N-KNX27. KNX/EIB Staircase Sensor Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
Lighting interval timers.
• N-KNX22. KNX/EIB Scene Controller Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2mm safety sockets.
Several presets to be load.
• N-KNX10. KNX/EIB Energy Meter Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
This module allows measure:
Active power.
Active energy.
Current.
Voltage.
• N-KNX30. KNX/EIB Touch Panel Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX25. KNX/EIB Single Line Extending Bus Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
Interconnection with other KNX/EIB systems.
• N-KNX2. KNX/EIB Additional Power Supply Module.
KNX bus voltage: 28 VDC.
Bus inputs/outputs: 2 mm safety sockets.
• All necessary cables to realize the practical exercises are included.
Cables and Accessories, for normal operation.
AEL-KNX4 | KNX/EIB LIGHTING CONTROL APPLICATION
The KNX/EIB Lighting Control Application, “AEL-KNX4”, has been designed by EDIBON to show the students the most important KNX elements used in the most advanced lighting control installations. Lighting control can be done through two methods: switching on and off the lights according to the sun light intensity or with a constant close loop control with which the light intensity is automatically adapted. These two methods allow to get energy savings whenever the KNX devices are programmed properly.
The purpose of the AEL-KNX4 is to give the students a complete practical and theoretical training in the installations and programming of the most important KNX elements focused in lighting control systems, characteristic of sensors, actuators, comparison of energy consumption with different lighting control systems and the conventional lighting elements, etc.
To take a maximum experience with the KNX/EIB Lighting Control Application is very recommendable to acquire the rest of the KNX offered by Edibon, AEL-KNX1, AEL-KNX2, AEL-KNX3 and AEL-KNX5. The combination of all these applications allows the student to design a complete intelligent bus system implemented by a KNX System.