The R&S®ENV4200 200 A four-line V-network meets CISPR 16‑1‑2, EN 55016-1-2, ANSI C63.4 and FCC Part 15 requirements for V-networks with an impedance of 50 μH || 50 Ω in the frequency range from 150 kHz to 30 MHz. The R&S®ENV4200 V-network measures RFI voltages on AC and DC supply connections for EUT carrying very high currents. The network has air-core inductances, an artificial hand and a pulse limiter.
SPECIFICATION
- Frequency range 150 kHz to 30 MHz
- Power handling capacity up to 200 A, constant current
- Simulated impedance 50 μH || 50 Ω in line with CISPR 16-1-2
- RFI voltage measurements in line with CISPR, EN, VDE, ANSI and FCC Part 15
- Calibrated in line with CISPR 16-1-2