SPECIFICATIONS
The “AEL-AD24” application includes the following elements:
• N-ALI02. Domestic Main Power Supply Module.
Supply voltage (single-phase): 230 VAC, 1PH + N.
ON/OFF removable key.
Output voltage connections:
Two single-phase: 230 VAC.
Single-phase supply hose with connecting plug.
Differential magnetothermal 2 poles, 25 A, 30 mA AC 6 KA.
Emergency stop push button.
• N-ALI03. AC Auxiliary Power Supply (24 Vac) Module.
Supply voltage (single-phase): 230 VAC, 1PH + N.
Output voltage:
Single-phase 24 VAC / 12 VAC.
24 VDC.
0 – 24 VDC through potentiometer.
• N-LAM03. 3 Push-buttons and Lamps Module.
Nominal voltage: 230 VAC.
Three lamps (red, yellow and green).
Three normally open push-buttons (red, yellow and green).
Contacts:
Three Normally Open contacts (NO).
• N-SEN01. Instantaneous Micro-Switch Module.
Instantaneous switch: NO and NC contacts.
Nominal voltage: 240 VAC.
Nominal current: 3 A.
Contacts:
One Normally Open contact (NO).
One Normally Close contact (NC).
• N-SEN02. MBB Micro-Switch Module.
Make before break action (MBB): continuous contact, NO contacts close before NC contacts open.
Nominal voltage: 240 VAC
Nominal current: 3 A.
Contacts:
One Normally Open contact (NO).
One Normally Close contact (NC).
• N-SEN03. BBM Micro-Switch Module.
Brake before make action (BBM): discontinuous contact, NC contacts open before NO contacts close.
Nominal voltage: 240 VAC.
Nominal current: 3 A.
Contacts:
One Normally Open contact (NO).
One Normally Close contact (NC).
• All necessary cables to realize the practical exercises are included.
Cables and Accessories, for normal operation
AEL-AD24 | POSITION SWITCHES APPLICATION
The Position Switches Application, “AEL-AD24”, has been designed by Edibon in order to demonstrate how the different safety switches work, such us MBB (Make before break), BBM (break before make) and instantaneous micro-switch. This kind of device consists of an actuator mechanically linked to a set of contacts. When an object comes into contact with the actuator, the device operates the contacts to make or break an electrical connection.
For instance, limit switches are used in a variety of applications and environments for their ruggedness, ease of installation, and reliability of operation. They can determine the presence or absence, passing, positioning, and end of travel of an object. They were first used to define the limit of travel of an object, hence the name Limit Switch.