SPECIFICATIONS
• N-KNX34. KNX/EIB USB Programming Interface Module.
Power supply: KNX line, 21…30 VDC.
Current consumption (max.): < 5 mA.
USB connection: USB2.0 connector.
• N-KNX18. KNX/EIB Power Supply Module.
Power supply: 230 VAC.
Maximum load: 640 mA.
Output voltage: 24 VDC.
• N-KNX4. KNX/EIB Binary Input Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX5. KNX/EIB Binary Output Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX12. KNX/EIB Fire/Smoke Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
Current:
Standby: 85 uA (approx.)
Alarm: 100 mA (approx.)
Operating temperature: – 10 º/+70 ºC.
• N-KNX13. KNX/EIB Flooding Sensor Module.
Nominal voltage: KNX bus voltage.
KNX bus voltage: 24 VDC.
Operating temperature: – 10 to +50 ºC.
• N-KNX17. KNX/EIB Movement Sensor Module.
Movement sensor for bus system KNX.
Max. Transmission range frontally 7m.
Number of channels 1.
• N-KNX26. KNX/EIB Siren Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
Working temperature: -5ºC to +45ºC.
Current: 200 mA.
Acoustic warning.
• N-KNX6. KNX/EIB Bolt Switch Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2mm safety sockets.
Working temperature: -20ºC to +60ºC.
Switching current: 300 mA (approx.)
• N-KNX7. KNX/EIB Broken Glass Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2mm safety sockets.
• N-KNX33. KNX/EIB Window/Door Contact Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX19. KNX/EIB Proximity Sensor Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
Working temperature: -5 ºC to +45 ºC.
• N-KNX15. KNX/EIB Magnetic Card Reader Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
Card operating speed: 10 cm/s to 120 cm/s.
Working temperature: -10ºC to +50ºC.
Working humidity: 20% – 90% RH.
• N-KNX11. KNX/EIB Fingerprint Reader Module.
KNX bus voltage: 24 VDC.
Bus inputs/outputs: 2 mm safety sockets.
Working temperature: -20 ºC to +50 ºC.
Working humidity: 30% – 85% RH.
• N-KNX30. KNX/EIB Touch Panel Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX35. KNX/EIB Infrared Transmitter/Receiver Module.
The IR remote is powered by two batteries of type Alkaline (LR03/AAA; 1,5V).
Normal functions:
Switching.
Switching and Dimming.
Control of blinds.
• N-KNX25. KNX/EIB Single Line Extending Bus Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
Interconnection with other KNX/EIB systems.
• N-KNX2. KNX/EIB Additional Power Supply Module.
KNX bus voltage: 28 VDC.
Bus inputs/outputs: 2 mm safety sockets.
• N-KNX3. KNX/EIB Barrier Sensor Module.
Nominal voltage: 230 VAC.
Frequency: 50 Hz.
KNX bus voltage: 24 VDC.
Mains inputs/outputs: 4 mm safety sockets.
Bus inputs/outputs: 2 mm safety sockets.
• All necessary cables to realize the practical exercises are included.
Cables and Accessories, for normal operation.
AEL-KNX3 | KNX/EIB SECURITY CONTROL APPLICATION
The KNX/EIB Security Control Application, “AEL-KNX3”, has been designed by Edibon to show the users the most important KNX elementsused in security alarm control systems with KNX technology.
The purpose of the AEL-KNX3 is to give the students a complete theoretical-practical training in the installations and programming of themost important KNX elements focused in security alarm control devices, characteristic of sensors, actuators, etc.
To take a maximum experience with the KNX/EIB Security Control Application is very recommendable to acquire the rest of the KNX offeredby Edibon: AEL-KNX1, AEL-KNX2, AEL-KNX4 and AEL-KNX5. The combination of all these applications allows the student to design acomplete intelligent bus system implemented by a KNX System.
In addition, this application requires the ETS latest generation KNX software to program different scenes, import of KNX projects, settingof sensors and actuators, etc.